ULTIMA® XE with HARTMSA’s well-proven ULTIMA® XE gas monitors with display are now available with HART field communications protocol [Highway Addressable Remote Transducer]. HART provides two-way digital communication between intelligent field instruments and host systems. Increased sensor data as well as convenient set-up, calibration and diagnostics can be offered for better management of plant assets.
HART features two simultaneous communication channels: the 4-20 mA analogue signal and a digital signal, enabling the user to perform convenient set-up, calibration and diagnostics from any point along the 4-20 mA line. With ULTIMA XE gas monitors the user has multiple calibration options: the handheld HART communicator, a laptop which communicates via dedicated HART software and the ULTIMA controller or calibrator.
[ Key Features ]
- HART protocol:
Digital communication from any point along the 4 –20 mA line or intrinsically safe port - Upgrade to HART by replacing PCB:
Flexibility and reduced installation costs - Sensor disconnect-under-power:
MSA’s patented sensor design allows sensor replacement without declassifying the hazardous area - Interchangeable smart sensors:
Pre-calibrated, installation-ready sensors are field-replaceable under power without tools - Same sensors for all versions:
Significant savings for plants already using ULTIMA X gas monitors - Various calibration & diagnostic options:
Hand-held HART communicator, host DCS or laptop for troubleshooting, calibration and configuration - LCD alternates between sensor reading & gas type:
Easy to view important information - Single-board design:
Provides reliability and easier serviceability - Rugged, explosion-proof stainless steel enclosure:
Suitable for indoor and outdoor applications in virtually any type of industry
[ ULTIMA® XE ]
- Combustible, oxygen and toxic gas monitoring
- Catalytic and electrochemical sensors
- Intrinsically safe HART port
- 316 stainless steel
- Multiple-entry mounting enclosure
- Ingress protection – IP 66
| Approvals & Standards |
|---|
Europe
- CE Low Voltage/EMC/ATEX
- II 2G Ex d [ib] IIC T4/T5
- IP 66
- EN 61779-1,EN 61779-4,
- EN 60079-0,EN 60079-1
USA/Canada
- cFM, cULus, CSA
- Class I, Div. 1, Groups A, B, C, D
- Class I, Div. 2, Groups A, B, C, D
- Class III
- ANSI/ISA 12.13.01
- CSA C22.2 No. 152
Class I, Div. 1, Groups A, B, C, D - CSA C22.2 No. 152
Class I, Div. 1, Groups B, C, D [XIR]
International
- IEC Ex d [ib] IIC T4
- IP 66
|
Hazards |
|---|
| Combustible Atmosphere | | Oxygen Deficiency | | Toxic Atmosphere (Non-IDLH) |
|